Abstract
Abstract Objective The aim of this study was to determine the normative percentiles for liver stiffness measurement (LSM) using shear wave elastography in an adult Asian Indian population as part of the preventive radiology initiative of the Indian Radiological and Imaging Association (IRIA). Methods LSMs were ascertained by two-dimensional (2D) shear wave elastography using the Mindray Resona series of ultrasound machines. The image quality was assessed using the motion stability index (M-STB) and reliability (RLB) map. Ten acquisitions were documented, and an interquartile range-to-median (IQR/M) ratio ≤30% kilopascal (kPa) units was considered a good-quality measurement. A subgroup of the study population without comorbidities was chosen to derive the normative percentile distribution of LSM using a generalized least squares multivariable fractional polynomial regression model that adjusted for sex and body mass index (BMI). The effectiveness of the estimated percentiles was assessed on the entire study population using the greater than 90th percentile value of the LSM as the cutoff for abnormality. Results The study included 852 people who underwent shear wave elastography from June 2022 to July 2023. The magnitude of compensated advanced chronic liver disease (cACLD) and clinically significant portal hypertension (CSPH) was 6.81% (95% confidence interval [CI]: 5.30–8.7) and 4.91% (95% CI: 3.67–6.60), respectively. The normative percentiles were estimated from 282 persons without associated comorbidity and risk factors. The mean age (standard deviation [SD]) of the normal individuals was 40.90 ± 12.92 years, and 210 (71.47%) were males. The mean age (SD) of the 570 persons excluded from the normative percentiles analysis was 47.94 (12.49) years and 72.11% were males. The sex- and BMI-adjusted age-specific 90th percentiles of LSM were 8.76, 8.78, 8.96, 8.97, 9.25, and 9.45 kPa for 18 to 20, 21 to 30, 31 to 40, 41 to 50, 51 to 60, and 61 to 70 years, respectively. Conclusion The sex- and BMI-adjusted age-specific 90th percentiles for LSM using shear wave elastography in Asian Indian adults are almost similar to the greater than 9 kPa cutoff proposed by the Society of Radiologists in Ultrasound Liver Elastography Consensus Statement guidelines to discriminate cACLD and CSPH from normal individuals.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.