Abstract

Inadequate stem version might lead to impingement and instability after cementless total hip arthroplasty (THA). We evaluated (1) the distribution of short-stem anteversion, (2) the proportion of stems with an anteversion less than 5° or larger than 25°, (3) combined cup and stem anteversion, and (4) dislocation rate. We evaluated the native femoral anteversion and stem anteversion in 340 patients (340 THAs): 144 men and 196 women. Their mean age was 56.2 (22-87) years and mean body mass index was 25.1 (15.2-40.7) kg/m2. The femoral neck anteversion was measured on pre-operative CT scan and the stem anteversion was obtained during the operation. The safe zone of the stem anteversion was defined as 5 to 25°. The femoral neck anteversion ranged from -15 to 61° (mean, 15.0°; SD, ±10.6°). The stem anteversion ranged -7 to 50° (mean, 15.7°; SD, ±9.5°). It was optimal (5-25°) in 71.2% (242/340), insufficient (<5°) in 13.3% (45/340), and excessive (>25°) in 15.6% (53/340). The stem anteversion had a medium correlation with the femoral neck anteversion (correlation coefficient = 0.449). The combined anteversion was 42.0° (range, 35.2-52.3°; SD, ±2.8°). During two to fouryear follow-up, no hip dislocated. Short-length stem had a great variability in the anteversion and considerable portion (28.9%, 98/340) of stems had an anteversion outside the safe zone. Surgeons should be aware of this variability of stem anteversion to compensate for abnormal stem anteversion, which might lead to impingement and instability after THA.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call