Abstract

This paper presents a distributed fault diagnosis scheme able to deal with process and sensor faults in an integrated way for a class of interconnected input–output nonlinear uncertain discrete-time systems. A robust distributed fault detection scheme is designed, where each interconnected subsystem is monitored by its respective fault detection agent, and according to the decisions of these agents, further information regarding the type of the fault can be deduced. As it is shown, a process fault occurring in one subsystem can only be detected by its corresponding detection agent whereas a sensor fault in a subsystem can be detected by either its corresponding detection agent or the detection agent of another subsystem that is affected by the subsystem where the sensor fault occurred. This discriminating factor is exploited for the derivation of a high-level isolation scheme. Moreover, process and sensor fault detectability conditions characterising quantitatively the class of detectable faults are derived. Finally, a simulation example is used to illustrate the effectiveness of the proposed distributed fault detection scheme.