Abstract

With increasingly prominent role of rail transit in the entire urban transport system, an auxiliary inverter is used increasingly. The complicated and fluctuating load condition of the auxiliary inverter implies special designs about structure and control strategy are necessary. For this purpose, a comprehensive control strategy is proposed. First of all, this paper proposes a structure that is capable of suppressing unbalanced voltage. Second, the control strategy based on the resonant controller is proposed, which can balance split capacitors voltage, is capable of suppressing the effect of unbalanced load and nonlinear load. This paper introduces the design method of the control system in detail. Then, this paper simulates the proposed comprehensive control strategy in MATLAB. Finally, experimental results are presented, which fully demonstrate the excellent performance of the comprehensive control strategy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.