Abstract

We investigated the possibility of surrounding waves along with perimeter of large diameter tendon ducts during ground penetrating radar (GPR) testing of concrete structures. The surrounding waves influence the primary reflection from tendon duct and alter the phase as well as amplitude of signal depending on the diameter of the tendon duct. This phenomenon was studied in detail by conducting several simulations using a commercial software Reflexw®. Finite Difference Time Domain method was adopted to analyze reflection patterns from objects of various diameters located at different depths in concrete media. The proposed methodology will be useful in qualitative assessment of size of metallic objects greater than a diameter of 6 cm. In general, the identification of large diameter tendon ducts in a civil structure is carried out by prior knowledge of the civil plan and its diagonal appearance to smaller diameter object mesh. The proposed methodology will enhance the confidence in identification of the larger diameter tendon ducts even if the civil plan is not known accurately.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.