Abstract

The third step of distance protection is used as backup protection against phase-to-phase short circuits on 110–220 kV transmission lines. The main problem when using these protections on a line with several branches is to ensure the effectiveness of distant backup protection in case of phase-to-phase short circuits behind branch transformers of substations. The effective solution to distant backup protection is possible to provide by expanding the information base of protection. Currently, backup protection of lines with branches is being developed with control of currents and their components when using a communication channel, and based on algorithmic models of the facility. In this regard, the urgent task is to develop an algorithm for the distance protection ensuring the required sensibility during short circuits on the lower voltage side of the branch transformers. Analytical methods of determining the impedance measurement and simulation in Simulink and SimPowerSystems of the Matlab modeling system are used. The effectiveness of distant backup protection can be evaluated on the basis of recognition possibility of short circuit modes behind the branch transformers. Analytical expressions have been obtained to determine the impedance measurement during phase-to-phase short-circuits behind a branch transformer and under load conditions. Criteria have been developed to assess the proposed protection possibility to recognize the mode of phase-to-phase short circuits behind the branch transformer. Studies have shown that the main factor determining the possibility of mode recognition is the ratio between the protected transformer power and the total power of the branches loads. The use of several impedance measuring elements with their own response characteristics for branches with transformers of different capacities provides mode recognition for any possible correlation of power of branch substations. The use of the distance protection implementation option developed by the authors allows providing the required sensitivity for short circuits behind branch transformers and to solve the problem of distance backup line protection on a line with several branches. The reliability of the data obtained is confirmed by the correspondence of analytical research and simulation results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.