Abstract

Aortic dissection is a major cardiovascular disease associated with a high mortality rate. In complicated type B dissection, with favorable anatomy, endovascular surgical repair (thoracic endovascular aortic repair [TEVAR]) is considered the treatment of choice. Intimomedial injury induced by stent graft, or stent graft-induced new entry (SINE), has a clinically significant incidence. SINE can occur at the proximal or distal level of the stent graft. The aim of this retrospective study was to investigate the incidence, mechanism, and predictive factors of late distal SINE. We reviewed 139 discharged patients after TEVAR for type B or residual aortic dissection after typeA surgery, from January 2007 to March 2013. Three intervalsof computed tomography imaging were collected, including before and after primary TEVAR and with the first detection of distal SINE. Four accessible measurement methods for precise size selection of the stent graft before and after the procedure were analyzed at the distal end level of the primary stent graft. Among the 139 patients, only 108 had complete preoperative and follow-up imaging and were enrolled in the study. The mean age of the patients was 59.7 ± 11.7 years, and 92 patients (85.2%) were men. Seventy had type B aortic dissection, and 38 had residual aortic dissection after type A surgery. The mean follow-up period was 36.1 ± 25.7 months. During follow-up, distal SINE occurred in 30 patients (27.8%), and 18 ofthem (60%) underwent secondary TEVAR whereas theremaining 12 patients were medically treated. No statisticallysignificant differences in demographic andclinical conditions were seen between patients with or patients without SINE. The incidence of SINE was lower for acute than for chronic dissection (16% versus 50%). At the multivariate analysis, the independent factorsassociated with SINE development were the oversizing ratio of the area (odds ratio 1.858; 95% confidence interval: 1.109 to 3.064; p= 0.018) and of the mean diameter (odds ratio 1.858; 95% confidence interval: 1.109 to 3.064; p= 0.018). Type B aortic dissection can be treated effectively with TEVAR. The incidence of distal SINE is not negligible but is not associated with poor outcomes. The main determinant of SINE seems to be an excessive oversizing, which is particularly evident in the distal end. More accurate sizing can be obtained by evaluating the area of the true lumen.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.