Abstract
In Fluent, the 3-D RNG k–ε mathematical model is employed to compute water and air mixture pipe flow. The dissolved oxygen convectionaεnd diffusion model is established to simulate the concentration distribution of dissolved oxygen with user defined scalar method. Velocity, pressure and dissolved oxygen concentration are computed. Then, dissolved oxygen concentration and pressure are compared with the data of physical model, and they agree with each other approximately, showing it is valid and reliable to compute the mixture pipe flow and dissolved oxygen concentration with the model .Furthermore, under a specific condition, velocity, pressure and dissolved oxygen concentration of water and air mixture pipe flow are computed and their characteristics are analyzed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.