Abstract

A dissolution test for mianserin hydrochloride in coated tablets containing 30 mg was developed and validated using a fast ultraviolet spectrophotometric method. The appropriate conditions were determinate after testing sink conditions, agitation spped and dissolution medium. The sink conditions tested showed that mianserin hydrochloride was soluble in 0.01 and 0.1 M hydrochloric acid (HCl), acetate buffer pH 4.1 and 5.0 and phosphate buffer pH 6.8. Then, dissolution tests were performed to investigate the drug release in each medium. Optimal conditions to carry out the dissolution test were 900 mL 0.1 M HCl and USP apparatus 2 (paddle) at 50 rpm stirring speed. The quantification method was also adapted and validated. The UV method showed specificity, linearity, precision and accuracy. The in vitro dissolution test can be used to evaluate the drug release profile and the data was used as an aid to establish a possible correlation with in vivo data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.