Abstract
Dissolving behavior of hydroxyapatite (HA) ceramics prepared from bovine bone (BHA) was investigated and compared with synthetic HA. BHA power was obtained by calcining at 800 °C for 1 h to remove organics and then attritor-milling for 24 h. Synthetic HA and BHA powders were prepared by hot-pressing at 1000 °C for 0.5 h under the pressure of 30 MPa in Ar atmosphere. Sintered densities of the synthetic HA and the BHA were about 96% and 95%, respectively. The BHA consisted of mainly HA and small amount of magnesium oxide. Immersion test revealed that there was no clear evidence of dissolution for the BHA, whereas extensive dissolution on the surface of the synthetic HA occurred in buffered water. Accordingly, dense hydroxyapatite from bovine bone was more stable than synthetic HA in liquid environment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.