Abstract

ObjectivesTo quantify the presence of two model highly permeable drugs, paracetamol and danazol, in the upper gastrointestinal lumen under conditions simulating the situation after disintegration of immediate release dosage forms administered in bioavailability/bioequivalence studies in the fed state. To understand the drug transfer process from the antral contents through the upper small intestine based on luminal drug data. Methods8 healthy male adult volunteers participated in a randomized, single dose, two-phase, crossover study. After evaluating the impact of homogenization on meal's viscosity and particle size, the meal, containing phenol red as non-absorbable marker, was administered to the antrum via the gastric lumen of a naso-gastro-intestinal tube. The drugs were administered in solution form (Phase I) and in suspension form (Phase II) with a glass of tap water to the antrum of the stomach, 30 min after the initiation of meal administration. Samples were aspirated from the antrum and the upper small intestine up to 4 hours post drug administration. ResultsApparent concentrations in the aqueous contents of the antrum were higher than apparent concentrations in the micellar contents of the upper small intestine for paracetamol; the opposite was observed for danazol. Based on total drug amount per volume data in contents of the upper gastrointestinal lumen, the transfer of paracetamol (aqueous solution or suspension) and danazol (aqueous suspension) through the upper small intestine could be described as an apparent first-order process. Transfer of a long-chain triglyceride solution of danazol was highly variable. ConclusionsConcentrations in the aqueous/micellar phase of luminal contents and values of parameters controlling the transfer from bulk gastric contents through the upper small intestine after a high-calorie, high-fat meal, were reported for the first time for highly permeable drugs. Data are expected to enhance the development of biorelevant in vitro and physiologically based biopharmaceutics modelling methodologies.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.