Abstract

Ten healthy volunteers underwent direct laryngoscopy using topical anaesthesia and a curved Macintosh laryngoscope blade. A lateral x-ray was performed during laryngoscopy in a standard intubating position. In this position the lower neck was relatively straight and increasing curvature occurred from the mid cervical spine upwards. Extension at the atlanto-axial joint was probably near maximum; this has implications for conditions associated with laxity of this joint. The position of the mandible was influenced by the direction of pull on the laryngoscope handle. The hyoid was drawn forward and its body tilted downwards so as to lie halfway between the lower border of the mandible and the glottis. The relative length of epiglottis projecting above the hyoid was variable.