Abstract
BackgroundMethamphetamine has an adverse effect on the ability to drive safely. Police need to quickly screen potentially impaired drivers therefore a rapid disposable test for methamphetamine is highly desirable. This is the first proof-of-concept report of a disposable electrochemical test for methamphetamine in undiluted saliva.ResultsA screen printed carbon electrode is used for the N,N′-(1,4-phenylene)-dibenzenesulfonamide mediated detection of methamphetamine in saliva buffer and saliva. The oxidized mediator reacts with methamphetamine to give an electrochemically active adduct which can undergo electrochemical reduction. Galvanostatic oxidation in combination with a double square wave reduction technique resulted in detection of methamphetamine in undiluted saliva with a response time of 55 s and lower detection limit of 400 ng/mL.ConclusionsUsing a double square wave voltammetry technique, rapid detection of methamphetamine in undiluted saliva can be achieved, however there is significant donor variation in response and the detection limit is significantly higher than desired. Further optimization of the assay and sensor format is required to improve the detection limit and reduce donor effects.Electronic supplementary materialThe online version of this article (doi:10.1186/s13065-016-0147-2) contains supplementary material, which is available to authorized users.
Highlights
Methamphetamine has an adverse effect on the ability to drive safely
This paper reports a mediated screen printed carbon electrode for the detection of methamphetamine in undiluted saliva using substituted N,N′-(1,4-phenylene)dibenzenesulfonamide mediator
The oxidized form of the mediator (II) reacts with secondary amines such as methamphetamine (MAMP) by 1,4-addition resulting in the reduced form of the MAMP-mediator adduct (III)
Summary
A screen printed carbon electrode is used for the N,N′-(1,4-phenylene)-dibenzenesulfonamide mediated detection of methamphetamine in saliva buffer and saliva. The oxidized mediator reacts with methamphetamine to give an electrochemically active adduct which can undergo electrochemical reduction. Galvanostatic oxidation in combination with a double square wave reduction technique resulted in detection of methamphetamine in undi‐ luted saliva with a response time of 55 s and lower detection limit of 400 ng/mL
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.