Abstract

Background: There is an ongoing debate if bone graft substitutes (BGSs) are beneficial in the treatment of displaced intra-articular calcaneal fractures (DIACFs). The purpose of this study was to evaluate the effect of an injectable calcium sulfate/hydroxyapatite BGS (CERAMENTTM iBONE VOID FILLER, BONESUPPORT AB, Lund, Sweden) in internal fixation of calcaneal fractures. Methods: The records of patients presenting with calcaneal fractures type Sanders III and IV and treated with internal fixation plus BGS were reviewed. Radiographs were analyzed using different measurements (including Bohler's angle and calcaneal facet height). The clinical outcome was evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale. Results: A total of 20 fractures were available for radiographic and clinical examination at a minimum follow-up of 12 months. No decrease in Bohler's angle was recorded in six fractures, a reduction of