Abstract

The redispersion factor of microbe-carrying particles, which is the ratio of the concentration of floor-derived microbes in room air to those on a floor surface, was determined, as was the percentage of floor-derived microbes in room air. These relationships were shown to vary according to conditions in the room. Equations were derived that allow these relationships to be calculated for a variety of room conditions, including air supply rates, levels of personnel activity, and the effect of gravitational deposition on microbe-carrying particles.The redispersion factor in ventilated rooms, such as cleanrooms and operating rooms, when the floor surface concentration was measured by nutrient agar contact dishes, was found to vary from about 1.5 × 10−4 to 7.4 × 10−6, and the percentage of floor-derived microbes in room air from about 0.004% to 10.5%. In a typical cleanroom, the redispersion factor is likely to be about 1.0 × 10−4, and the percentage of floor-derived microbes, 0.7. In a typical operating room, the redispersion factor is likely to be about 5.2 × 10−6 and the percentage of floor-derived microbes, 2.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.