Abstract Mean gas holdup, lateral distribution of gas holdup and axial mixing of gas and liquid were measured in bubble columns of 12 and 19cm i.d. The lateral distribution of gas holdup was strongly dependent on the flow regimes in the column. The axial mixing of liquid in the homogeneous bubble flow regime was much smaller than that in the heterogeneous bubble flow regime, and was not expressed by existing correlations. The axial mixing of liquid in the homogeneous bubble flow and the intermediate flow regime was simulated with a flow model based on the lateral distribution of buoyancy force and the effective viscosity. The axial mixing of gas was larger than that of liquid.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.