Abstract

Objective lenses are frequently employed in state-of-the-art ultrafast time-resolved microscopy techniques. While it enables tight spatial focusing, its dispersion causes a longer optical pulse duration. Since an objective lens is a combination of different lens materials, finding its correct dispersion can be challenging. In this paper, we propose a dispersion measurement method for an objective lens using white light interferometry. Our proposed method enables the experimental determination of the lens dispersion and improves the temporal resolution of ultrafast time-resolved microscopy techniques.