Abstract

Direct current applied to a tin oxide anode submersed in water has the potential to generate hydroxyl radicals, a strong chemical oxidant. Tin oxide anode systems, which may represent a viable alternative disinfectant, were investigated for the disinfection of secondary effluents. Coliform bacteria in the effluent were effectively inactivated in a bench-scale tin oxide disinfection system. The number of anodes in the tin oxide disinfection system influenced the steady-state concentration of hydroxyl radicals and, consequently, the contact time necessary to achieve a specified dose. The life expectancy of the anodes was greater than 30 days and no appreciable loss of tin was observed over a 5-day period. A preliminary estimate of the capital and operating costs of a pilot- or full-scale tin oxide disinfection system designed to meet a discharge requirement of 23 most probable number/100 mL at a 3 785-m3/d (1-mgd) facility was comparable to UV and chlorination/dechlorination facilities. Based on this preliminary assessment, tin oxide disinfection systems are a promising alternative disinfectant for secondary effluents.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.