Abstract
This paper proposes a dual-loop discrete-time adaptive control (DDAC) method for three-phase PWM rectifiers, which considers inductance-parameter-mismatched and DC load disturbances. A discrete-time model of the three-phase PWM rectifier is established using the forward Euler discretization method, and a dual-loop discrete-time feedback linearization control (DDFLC) is given. Based on the DDFLC, the DDAC is designed. Firstly, an adaptive inductance disturbance observer (AIDO) based on the gradient descent method is proposed in the current control loop. The AIDO is used to estimate lump disturbances caused by mismatched inductance parameters and then compensate for these disturbances in the current controller, ensuring its strong robustness to inductance parameters. Secondly, a load parameter adaptive law (LPAL) based on the discrete-time Lyapunov theory is proposed for the voltage control loop. The LPAL estimates the DC load parameter in real time and subsequently adjusts it in the voltage controller, achieving DC load adaptability. Finally, simulation and experimental results show that the DDAC exhibits better steady and dynamic performances, less current harmonic content than the DDFLC and the dual-loop discrete-time PI control (DDPIC), and a stronger robustness to inductance parameters and DC load disturbances.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.