Abstract

The paper presents a new algorithm for detecting the presence of measurement discontinuities in scanning measurements carried out on coordinate measuring machines (CMMs). The proposed algorithm marks the regions that are inaccessible to the stylus tip. This allows the machine user to decide whether to change the tip for a smaller one. The method is for use in a high-definition coordinate metrology (HDCM) context, where the density of points per scanned distance ensures that the successive probe ball positions overlap partially with each other and can be applied directly to the data collected during a measuring process. The paper describes the operating principle of the new algorithm and experimental verification on a Zeiss ACCURA CMM with an active VAST Gold scanning probe.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.