Abstract

Diaphragm activity (Edi, 20 Hz low cutoff) was recorded with great time resolution to ascertain whether there is a discontinuity between its inspiratory and postinspiratory periods in humans. We first determined in anesthetized rabbits that gaps or notches in Edi occurred within 80 msec before and after the end of mechanical inpsiration in 70% of the analysable breaths in the esophageal lead and in 77% in direct leads. We then determined from teh esophageal lead ot 4 conscious subjects that gaps or notches in Edi occurred during the above-defined period in 45% of 682 analysable breaths. In each subject mean of moving average Edi (12 msec averaging interval) was computed out of 14–24 breaths, free of ECg artifacts within 200–250 msec before and after end inspiration. A deep indentation occurred near end-inspiration despite the lack of gaps or notches in 1 2 to 4 5 of these breaths. These results suggest that also in humans postinspiratory diaphragm activity does not represent the decay of inspiratory ramp.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.