Abstract

Rehabilitation of ageing power plant is a growing market with specific needs: we have to deal with non up-to-date elements in terms of hydraulic behavior. Refurbishment projects are often focused on the guide vane and runner modification. But for low-head refurbishment projects, the draft-tube is a non negligible part of the overall performance. In some cases, pathological draft-tubes have been encountered with a significant efficiency drop near the best efficiency point. Modification of the draft-tube in order to attenuate, and even eliminate, this effect can thus have a real impact on improving the performance of the power plant, and therefore become economically justified (that heavily depends on the addition or removal of material from the draft-tube walls). Laser Doppler Velocimetry (LDV) measurements near draft-tube outlet have been achieved for both original and modified draft-tube. It offers 2D velocity profiles and permits to calculate discharge repartition in each bay. Pressure recovery factor measured separately for each bay is used to quantify losses.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.