Abstract

This paper presents an experimental campaign conducted next to the Condoroma dam, in Perú, at 4075 m a.s.l. The tests carried out in this paper were conducted in a 21 m long channel located at the toe of Condoroma dam. The setup consisted of a series of standard profile spillways with a vertical upstream face of up to five different dimensionless heights (P/Hd) ranging from 0.5 to 2. The experimental results indicated that, the P/Hd ratio influences the discharge coefficients in Condoroma, and P/Hd ≥ 1 values are recommended for the design of the spillway profile. In addition, for all the P/Hd ratios studied, the discharge coefficients adjusted to the Condoroma altitude were lower than those reported by classical formulations used in conventional spillway designs. Finally, a generalized equation is proposed to estimate the discharge coefficient for standard spillways located in dams at similar elevations above sea level.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call