Abstract

This paper presents the discharge coefficients of three film-cooling hole geometries tested over a wide range of flow conditions. The hole geometries include a cylindrical hole and two holes with a diffuser-shaped exit portion (i.e., a fan-shaped and a laidback fan-shaped hole). The flow conditions considered were the crossflow Mach number at the hole entrance side (up to 0.6), the crossflow Mach number at the hole exit side (up to 1.2), and the pressure ratio across the hole (up to 2). The results show that the discharge coefficient for all geometries tested strongly depends on the flow conditions (crossflows at hole inlet and exit, and pressure ratio). The discharge coefficient of both expanded holes was found to be higher than of the cylindrical hole, particularly at low pressure ratios and with a hole entrance side crossflow applied. The effect of the additional layback on the discharge coefficient is negligible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.