Abstract
Experimental measurements of discharge coefficient and effectiveness of conical shaped film cooling holes with 1°, 2° and 3° uniform diffusion angle are presented. All film holes are inclined at 35° with hole length to diameter ratio, L/D = 3.5, pitch to diameter ratio, PI/D = 3 with a constant density ratio of 1.26 and with nitrogen as the coolant. Results show that conical film holes have higher discharge coefficients than their cylindrical counterparts. For conical holes, the local distribution and laterally averaged effectiveness values decrease with increasing blowing ratio from 0.45 to 1. The configuration with 3° uniform diffusion angle has the highest effectiveness values and outperforms the conical holes with 1°, 2° diffusion angles by 40% in the proximity of the holes (X/D ≪ 5) at a blowing ratio of 0.45. Results are compared to base line cylindrical as well as to fan shape film holes available in open literature. The average effectiveness of the conical holes can reach values comparable to those achieved by fan shaped film holes at the same blowing ratio.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.