Abstract

AbstractLightning strikes not only metallic objects such as transmission towers and lightning rods but also insulated material such as blades of wind turbines. The discharge characteristics of insulated material are, however, not clarified till now. In this paper, discharge characterisitics of insulated material have been investigated experimentally using a 12‐MV impulse generator. The effects of polarities of the applied voltages and surface conditions of the insulation material are also studied and it is found that pollution on the surface decreases the sparkover voltage drastically. Copyright © 2007 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.