Abstract

Low-frequency transformer is the key equipment of flexible low-frequency AC transmission systems for offshore wind power. As the low-frequency voltage is applied, the transformer has significantly different insulation characteristics from those of the conventional transformer, it is necessary to study the typical characteristics of partial discharge of oil-paper insulation under such voltage. In this dissertation, the characteristics of discharge of needle plate electrodes in transformer oil under power frequency to low-frequency voltage are experimentally researched by adopting the pulse current method, and the discharge statistics, discharge atlas as well as feature parameters are analysed. With the decreasing of voltage frequency, the inception voltage (IV) value of partial discharge slightly increases, the extinction voltage (EV) phases of positive half-cycle (PHC) voltage waveform, as well as negative half-cycle (NHC) voltage waveform appear earlier, and the maximum discharge (MD), average discharge (AD), and pulse repetition rate (PRR) all show a downward trend.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.