This paper proposes a method for separation of broken rotor bar failures from low-frequency load torque oscillation in direct torque control (DTC) induction motor drives by using vq voltage and iq current components’ spectra. The effect of load torque oscillation should be considered in induction motor drives for reliable broken bar fault detection. Induction machine drivers are run in DTC mode to control its torque and speed. In practice, the presence of load torque fluctuation may sometimes cause false positive alarms on stator current spectrum. However, discerning of broken rotor bar failure from low-frequency load variation for DTC drives remains unexplored. Experimental results show that by using the proposed method broken rotor bar failure can be reliably detected in the presence of low-frequency load torque oscillation in DTC induction motor drives.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.