A Discfilter with 10 and 18 microm filter openings, respectively, was placed in parallel to a flotation plant for separation of biological flocs from a post-denitrifying Kaldnes Moving Bed Process, the last treatment step at the municipal wastewater treatment plant at Sjöunda, Malmö, Sweden. The effluent concentrations from the 10 and 18 microm filter were 2-5 and 2-8 mg SS L(-1), respectively, which is comparable to, or better than, the flotation plant. Comparison with experiences from activated sludge plants shows that the Discfilter works especially well after the Kaldnes process. Particle size distribution (PSD) studies show that particles larger than the filter openings of 10 and 18 microm are separated with approximately 90% efficiency, whereas most of the smaller particles pass the filter. This fact indicates that the major particle separation mechanism is physical blocking. These findings point to the possibility of improving the prediction of the separation efficiency by combining measurements of turbidity and suspended solids with particle size analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.