Abstract

The objective of this study was to assess long-term durability of bridging stents in branched and combined branched and fenestrated endovascular aneurysm repair (B/F-EVAR) for thoracoabdominal aortic aneurysm (TAAA) and pararenal abdominal aortic aneurysm.A retrospective database analysis was performed of patients treated by B/F-EVAR for TAAA. Computed tomography angiography images were analyzed to assess patency, bridging stent angulation and migration, aneurysm diameter, and migration of the endograft.Twenty-eight patients with a median age of 70 years (interquartile range [IQR], 67-77 years) were included. Assisted technical success was 89%. Within 30 days postoperatively, five patients died. In the remaining 23 patients, median follow-up was 5.3 years (IQR, 2.9-7.2 years), and 1-, 3-, and 5-year estimated overall survival was 69%, 65%, and 44%, respectively. During follow-up, 12 of 47 (26%) branches occluded and 5 of 47 (11%) branches developed a 70% to 99% stenosis. The 1-, 3-, and 5-year estimated freedom from adverse events was 78%, 76%, and 59% for branch stents and 100%, 96%, and 90% for fenestration stents, respectively. The median distal bridging stent migration was 0.5 mm (IQR, −1.9 to 1.4; P > .05 mm). In 10 branches, migration >10 mm was seen, ranging from 14.1 mm sliding in to 23.0 mm sliding out. The angulation between branch and stent became 4 degrees more angulated (IQR, −14 to +2 degrees). In 23 branches, the angulation changed 10 degrees or more, leading to an occlusion in 7 branches, a 70% to 99% stenosis in 3 branches, and a 50% to 70% stenosis in 4 branches. In three cases, the endograft migrated >5 mm caudally, with a breach in a fenestration stent in one and a breach in a branch stent in another.The anatomic configuration of branches in B/F-EVAR of TAAAs and pararenal abdominal aortic aneurysms changes over time. The change in angle of branches and the bridging stent influences the likelihood of stenosis and occlusion. Follow-up of B/F-EVAR should include computed tomography angiography measurements of aortic diameter, endograft migration, target vessel stent length, and angulation to detect disconnection, stenosis, and occlusion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.