Abstract
Studies involving micropuncture and microperfusion of single nephrons require the handling of very small fluid samples. To facilitate handling, the tubule fluids are normally manipulated under paraffin oil. Calcium and, to a lesser extent, magnesium and phosphate concentrations may change significantly when placed in hydrated paraffin oil. Fluids of alkaline pH (about 7.4), either intrinsic or because of loss of CO2, may very quickly lose calcium in paraffin oil. Evidence suggests that this is due to a reversible binding of calcium and perhaps magnesium to the aqueous-oil interface that is dependent on the pH of the sample. It is recommended that tubule fluid samples be kept acidic to prevent calcium loss. A convenient method is by equilibrating the paraffin oil, prior to placement of aqueous samples, with a CO2 tension sufficient to lower the sample pH to below 7.0.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.