Abstract
Suspended membranes of two-dimensional (2D) materials are of interest for many applications. Much of their characterization relies on scanning probe microscopy (SPM) techniques such as atomic force microscopy (AFM) or scanning tunneling microscopy (STM). Unlike rigid samples, the suspended atomically thin 2D membranes are, however, flexible and do not remain mechanically undisturbed during SPM measurements. Local deformations can occur at the location of the scanning tip and thus result in measurements that misrepresent actual membrane topography and nanomechanical properties. Exact levels of such SPM tip-induced deformations in 2D membranes remain largely unknown, as they are to date only indirectly accessible via dual probe microscope concepts that either are not mechanically independent (e.g., SPM-SPM setups resulting in complicated imaging crosstalk) or suffer from intrinsically limited lateral resolution (e.g., optical far-field techniques as the second probe). Circumventing these shortcomings, we here demonstrate that by coupling an AFM with a scanning electron microscope (SEM) as the second, mechanically independent probe, we can directly and in situ visualize by SEM at high resolution 2D membrane deformations that result from controllable AFM tip manipulations in the nN range. Employing few-layer graphene as model membranes, we discuss the experimental realization of our coupled in situ AFM-SEM approach.
Highlights
Scitation.org/journal/apl shown that, unlike for rigid materials/surfaces, scanning probe microscopy (SPM) techniques do not leave the flexible 2D membranes mechanically undisturbed during measurements.[11,12,13,14,15,16,17,18,19,20,21,22] Instead, SPM can result in membrane deformations at the location of the scanning tip
Much of their characterization relies on scanning probe microscopy (SPM) techniques such as atomic force microscopy (AFM) or scanning tunneling microscopy (STM)
Exact levels of such SPM tip-induced deformations in 2D membranes remain largely unknown, as they are to date only indirectly accessible via dual probe microscope concepts that either are not mechanically independent (e.g., SPM-SPM setups resulting in complicated imaging crosstalk) or suffer from intrinsically limited lateral resolution
Summary
Scitation.org/journal/apl shown that, unlike for rigid materials/surfaces, SPM techniques do not leave the flexible 2D membranes mechanically undisturbed during measurements.[11,12,13,14,15,16,17,18,19,20,21,22] Instead, SPM can result in membrane deformations at the location of the scanning tip.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.