Abstract
A new facility for the measurement of the normal spectral emissivity of solid materials for high-temperature applications in the thermal steady state was developed at the Bundeswehr University of Munich. The measurements are performed under atmospheric conditions. The facility covers the temperature range between \(500\,^{\circ }\hbox {C}\) and \(1350\,^{\circ }\hbox {C}\) and wavelengths between \(0.6\,\upmu \hbox {m}\) and \(15\,\upmu \hbox {m}\). The principle of operation involves the spectral comparison of a test sample with a reference blackbody and the sample surface temperature determination with a numerical spectral ratio calculation. The optical characteristics of the blackbody and the sample surface temperature determination are discussed in detail. Furthermore, measurement results of the quasi-reference material silicon-carbide under steady-state conditions are presented to validate the measurement method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.