Abstract

A direct measurement method for investigating the electrocaloric (EC) effect was developed using a thin-film thermocouple deposited on samples. A T-type thin-film thermocouple was fabricated by RF magnetron sputtering at room temperature. Two types of measurement were carried out using rectangular pulses and sine waves with a DC offset. The EC coefficients (ΔT/ΔE) of BaTiO3 ceramics were determined as 0.35 × 10−6 and 0.48 × 10−6 K·m/V in the measurements at Curie temperature. The EC temperature change of a (Ba0.9,Ca0.1)TiO3 thin film was measured using sine waves with the DC offset. The EC coefficient was 0.0018 × 10−6 K·m/V at room temperature. These results suggest that thin-film thermocouples are useful for the direct measurement of the EC effect.