Abstract
The glucuronide of N-1-hydroxy-ethyl flurazepam has been analysed by a direct liquid inlet liquid chromatographic/mass spectrometric system using MeOH/H2O (70:30 v/v) as mobile phase, at a flow rate of 0.7 ml min-1. Urine samples were purified by amberlite XAD-2 chromatography; the glucuronide was quantified by high-performance liquid chromatography using a counterion (tetrabutyl ammonium nitrate in methanol). Chromatographic results were validated by an enzymatic method: treatment of the samples with beta-glucuronidase and extraction of the parent drug with ethyl ether at pH 9. The biological application of this method was demonstrated by determination of this glucuronide in the urine of healthy human volunteers following a single intravenous administration of 50 mg of N-1-hydroxy-ethyl flurazepam.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.