Abstract

A rapid assay has been developed for on-line SPE-HPLC determination of trimethoprim in milk. SPE precolumns packed with reversed-phase sorbent (RPS C-18) and with restricted access material (ADS C-18) have been tested in the column switching system. Only a simple preparation procedure for the milk sample is required before the direct injection. A Symmetry C-18 analytical column and mobile phase consisting of 100 mM phosphate buffer (pH3), with the addition of an ion-pair agent (PSA) and acetonitrile, have been used for HPLC analysis. UV detection was performed at 229 nm. The detection limit for trimethoprim in milk was 5 ng/mL.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.