Abstract

Cyclic voltammetry is employed to demonstrate feasibility of direct electron transfer of glucose oxidase and D-amino acid oxidase at a glassy carbon electrode in organic media. The reversible slight conformational change of glucose oxidase is observed by changing 0.1 mol/L phosphate buffer to acetonitrile containing 10% v/v of water and 0.05 mol/L tetrabutyalammonium perchlorate, and vice versa.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.