Abstract
Electrospray ionization mass spectrometry was tested for its potential use in the quantification of monobutyl phosphate (H2MBP) and dibutyl phosphate (HDBP), two degradation products of tributyl phosphate (TBP), the extractant used in the nuclear fuel reprocessing known as the PUREX process. Detection and quantification of these phosphate esters by electrospray in positive and negative ionization mode are reported in this study. This fast and reliable method, which does not require any preliminary sample extraction, appears to be very attractive for process control. Negative ionization mode gave abundant [M - H]- ions for both HDBP and H2MBP products. Thus, the concentration of H2MBP between 0.1 and 10 g/L in concentrated aqueous nitrate solutions can be precisely determined. Moreover, the concentration of HDBP up to 1 g/L in a TBP matrix was evaluated in this mode. For HDBP concentrations below 1 g/L, detection in the positive ionization mode appeared to be attractive. TBP and HDBP cluster detection allowed quantitative HDBP determination. Indeed, small amounts of HDBP in commercial TBP (60 mg/L) could be directly quantified using the specific [2TBP, HDBP + H]+ cluster at m/z 743.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.