Abstract

A μElution solid-phase extraction (SPE) liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for simultaneous determination of diazepam, nordiazepam, oxazepam, oxazepam glucuronide, temazepam and temazepam glucuronide in human whole blood is presented. 200μL of whole blood samples were loaded onto a Waters Oasis HLB 96-well μElution SPE plate using 75μL of methanol as the elution solvent, and the eluents were injected into an Eclipse XDB C18 column. No hydrolysis, solvent transfer, evaporation or reconstitution was involved in the sample preparation procedures. Tandem mass spectrometric detection with Turbo Ion Spray was conducted via multiple reaction monitoring (MRM) under positive ionization mode. The method was validated and proved to be accurate (accuracy within 93–108%), precise (intra-day RSD<9.9% and inter-day RSD<7.2%) and sensitive with limits of detection (LOD) in the range of 0.05–0.25ng/mL for all the compounds. Extraction recoveries were in the range of 31–80% for all the analytes. This method demonstrated to be reproducible and reliable. The applicability of the method was demonstrated by analysis of several forensic cases involving diazepam and its metabolites.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.