Abstract

Hitec E580 is added to aviation fuel as an antiwear agent and corrosion inhibitor. The normal concentration range is 10-20 ppm and the level may be determined by measuring the concentration of the major active ingredient, namely dimer acid (technical-grade dilinoleic acid). The method of Hillman et al. involves multiple extractions of the dimer acid from a large volume of fuel and measurement is achieved by gel-permeation chromatography (GPC) with refractive index detection. This paper describes an improved method. It uses an on-line precolumn, containing a polar packing, to extract the dimer acid from the fuel. Operation of a switching valve allows the precolumn to be flushed with tetrahydrofuran (THF), thus transferring the dimer acid to a GPC column. Refractive index detection is used. The two methods give results which are in acceptable agreement

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.