Abstract

Elephant endotheliotropic herpesvirus (EEHV) causes a fatal hemorrhagic disease and is a significant cause of mortality in juvenile Asian elephants. A loop-mediated isothermal amplification (LAMP) method was developed to rapidly diagnose EEHV viremia. However, extracting DNA from whole blood samples to perform LAMP hampers diagnosis in a field setting. Here, we established the Direct-LAMP method, using heparinized plasma without extracting the DNA to speed up and simplify the test. EEHV-positive specimens were tested using the Direct-LAMP. The detection limit was calculated to be 101.3 copies/μL using the mimetic samples, which was almost identical to the value determined in LAMP in which DNA was extracted. Hence, the Direct-LAMP provided a more rapid diagnosis to save, which could prevent elephant deaths.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.