Abstract

To test the hypothesis that temporal variations in microvessel red cell flux cause unstable oxygen levels in tumor interstitium, extravascular oxygenation of R3230Ac mammary tumors grown in skin-fold window chambers was measured using recessed tip polarographic microelectrodes. Red cell fluxes in microvessels surrounding pO2 measurement locations were measured using fluorescently labeled red cells. Temporal pO2 instability was observed in all experiments. Median pO2 was inversely related to radial distance from microvessels. Transient fluctuations above and below 10 mm Hg were consistently seen, except in one experiment near the oxygen diffusion distance limit (140 microm) where pO2 fluctuations were <2 mm Hg and median pO2 was <5 mm Hg. Vascular stasis was not seen in these experiments. These results show that fluctuations in red cell flux, as opposed to vascular stasis, can cause temporal variations in pO2 that extend from perivascular regions to the maximum oxygen diffusion distance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.