Abstract

A MAJOR IMPROVEMENT in the cooling of field windings of turbine generators has been developed by the General Electric Company and applied for the first time in a 125,000-kva (30-pounds-per-square-inch-gauge hydrogen pressure) 3,600-rpm turbine generator now in the Huntley Station of the Niagara Mohawk Power Corporation at Buffalo, N. Y. Figure 1 shows the field of this machine. The new cooling arrangement has been proved successful in factory tests, which showed that at full 30-psig capacity, the temperature rise of the field winding is only about 25 per cent of that of otherwise duplicate fields of standard design previously tested. This indicates that for the same temperature rise, the new field could have its 30-psig capacity doubled, to 250,000 kva. Because of a requirement that the generator field be interchangeable with the fields of several previous machines of the same capacity, it was not feasible to take advantage of the improved cooling to reduce the physical size of this particular generator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.