Abstract
Portable cerebral perfusion studies provide a quick and accurate alternative to traditional confirmatory examinations (such as four-vessel angiography and electroencephalography) to determine brain death. The authors retrospectively analyzed 26 cerebral perfusion studies using both Tc-99m DTPA and Tc-99m HMPAO. The flow agents gave identical results. Additionally, the delayed-phase Tc-99m HMPAO images gave the same results for brain death (14 positive and 12 negative) as the flow images from either agent. Because the Tc-99m HMPAO delayed images can be used for diagnosis, many technical problems become less crucial. Unlike Tc-99m DTPA, Tc-99m HMPAO normally visualizes the gray matter of the cerebellum, midbrain, and medulla. These areas must be evaluated to ensure that they meet the strict criteria for brain death. These differences and the present study suggest that Tc-99m HMPAO is a superior agent for cerebral perfusion studies to determine brain death.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.