Abstract

A sensitive and simple micromethod for the accurate measurement of GMP reductase (EC 1.6.6.8) activity in crude extracts is described. The reaction product of [8- 14C]IMP was separated from the substrate [8- 14C]GMP by descending chromatography on Whatman DE81 ion-exchange paper. This separation method provides an analysis of the possible interfering reactions, such as the metabolic conversion of the substrate GMP to GDP, GTP, and/or guanosine, and guanine and the loss of the product IMP to inosine, hypoxanthine, and other metabolites. Low blank values (70–90 cpm) were obtained consistently with this assay because the IMP spot moves faster than the GMP spot. The major advantages of this method are direct measurement of GMP reductase activity in crude extracts, high sensitivity (with a limit of detection of less than 10 pmol of IMP production), high reproducibility (< ± 5%), and capability to measure activity in small samples (9 μg protein).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.