Abstract

To evaluate the influence of short versus long stems implanted through a Direct Anterior Approach (DAA) on clinical and radiological outcomes in THA at medium-term follow-up (average follow-up of 44.8months). 167 consecutive total hip arthroplasties treating patients affected by primary hip osteoarthritis were retrospectively evaluated. A standard-length stem (H-MAXs) was used in 70 patients, while a short metaphyseal-fitting femoral stem (MINIMA) was used in 97 patients. The Harris Hip Score (HHS) and Forgotten Joint Score-12 (FJS) were used as outcomes measurements. Post-operatively, Engh's score and Brooker classification were analyzed at 6months, 1year and every 2years until the final FU. The correct size of the implant was evaluated determining the canal fill index (CFI), and all undersized stems were classified according to Magra classification. The average HHS was 83 ± 13.4 in the standard stems group and 87 ± 14.1 for short stems group (p = 0.148). The average FJS was 87.9 ± 15.2 for patients in the standard stems group and 84.5 ± 17.7 with no significant differences (p = 0.327). None of the stems showed radiographic signs of instability (standard stems mean Engh's score: 19.25 versus short stems mean Engh's score: 19.50-p = 0.41). According to Brooker classification, no significant difference in severity was found using different stems (p = 0.715). A high rate of undersized stems was found (standard stems 24%-short stems 25%) but without statistical difference between groups (p = 0.078), while a different trend in malposition following the recent classification proposed by Magra et al. was observed evaluating all undersized stems (p = 0.0387). Both groups achieved good and comparable patient-reported outcome measurements (PROMs) and radiographic stability with fixation observed by bone ingrowth. A high rate of undersized stems was found with a correlation between femoral stem length and specific pattern of malposition. Malalignment in Varus was frequent in shorter stems in contact proximally with medial calcar and distally with lateral cortex, while a uniform undersizing was observed for longer ones with a continuous margin around the stem. However, the stems never presented progressive radiolucent lines over the whole surface of the stem.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.