Abstract

Trace-level inorganic anions in seawater are separated efficiently by capillary zone electrophoresis using direct UV detection. The carrier electrolyte is 50 mM borate at pH 9.3 and contained 1.5M NaCl. This buffer solution is adopted to prevent interference from high concentrations of the chloride ion in seawater. No electro-osmotic flow reverser is used to shorten the analysis time. The experimental conditions such as the concentration of NaCl in the carrier electrolyte, capillary inner diameter, applied current, and temperature are optimized. Linear plots are obtained in the concentration range of 0.1 to 20 microg/mL. The quantitation limits of the anions are in the order of 0.02 to 0.1 microg/mL. The proposed method may be applicable to the determination of inorganic anions in other environmental samples and effluents of a power plant.