Real time analysis of human breath is achieved in an atmospheric pressure ionization mass spectrometer (API-MS) by negatively charging exhaled vapors via contact with an electrospray cloud. The spectrum observed is dominated by a wide range of deprotonated fatty acids, including saturated chains up to C14. Above C14, the background from cutaneous sources becomes dominant. We also tentatively identify a series of unsaturated fatty acids (C7-C10), ketomonocarboxylic acids (C6-C10), and a family of aldehydes. The ionization probability of large fatty acids increases drastically when the humidity changes from 20% to 95%. Accordingly, distinguishing lung vapors (humid) from those in the background (dry) requires special precautions. Estimated fatty acid vapor concentrations in breath based on our measurements ( approximately 100 ppt) are in fair agreement with values expected from blood concentrations in the range for which data are available (C3-C6).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.