Abstract

Therapeutic drug monitoring (TDM) is necessary for the optimal administration of anti-arrhythmic drugs in the treatment of heart arrhythmia. The present study aimed to develop and validate a direct analysis in real time tandem mass spectrometry (DART–MS/MS) method for the rapid and simultaneous determination of five anti-arrhythmic drugs (metoprolol, diltiazem, amiodarone, propafenone, and verapamil) and one metabolite (5-hydroxy(OH)-propafenone) in human serum. After the addition of isotope-labeled internal standards and protein precipitation with acetonitrile, anti-arrhythmic drugs were ionized by DART in positive mode followed by multiple reaction monitoring (MRM) detection. The use of DART–MS/MS avoided the need for chromatographic separation and allowed rapid and ultrahigh throughput analysis of anti-arrhythmic drugs in a total run time of 30 s per sample. The DART–MS/MS method yielded satisfactory linearity (R2 ≥ 0.9906), accuracy (86.1–109.9%), and precision (≤ 14.3%) with minimal effect of biological matrixes. The method was successfully applied to analyzing 30 clinical TDM samples. The relative error (RE) of the concentrations obtained by DART–MS/MS and liquid chromatography-tandem mass spectrometry (LC–MS/MS) was within ± 13%. This work highlights the potential usefulness of DART for the rapid quantitative analysis of anti-arrhythmic drugs in human serum and gives rapid feedback in the clinical TDM practices.

Highlights

  • Therapeutic drug monitoring (TDM) is necessary for the optimal administration of anti-arrhythmic drugs in the treatment of heart arrhythmia

  • Direct Analysis in Real Time (DART)–MS/MS conditions were optimized in an attempt to achieve sharp and selective peaks with maximum intensity

  • We developed a DART–MS/MS method for absolute and simultaneous quantitative analysis of metoprolol, diltiazem, amiodarone, propafenone, 5-hydroxy(OH)-propafenone, verapamil in human serum

Read more

Summary

Introduction

Therapeutic drug monitoring (TDM) is necessary for the optimal administration of anti-arrhythmic drugs in the treatment of heart arrhythmia. The present study aimed to develop and validate a direct analysis in real time tandem mass spectrometry (DART–MS/MS) method for the rapid and simultaneous determination of five anti-arrhythmic drugs (metoprolol, diltiazem, amiodarone, propafenone, and verapamil) and one metabolite (5-hydroxy(OH)-propafenone) in human serum. The use of DART–MS/MS avoided the need for chromatographic separation and allowed rapid and ultrahigh throughput analysis of anti-arrhythmic drugs in a total run time of 30 s per sample. A rapid quantitative method with acceptable accuracy and precision is very needed for the TDM analysis of the anti-arrhythmic drugs. We aimed to develop and validate a simple, rapid and reliable DART tandem mass spectrometry (DART–MS/MS) method for the determination of five anti-arrhythmic drugs and one metabolite in human serum. The validated DART–MS/MS method was applied to the rapid and quantitative analysis of clinical TDM samples

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.