Abstract

Major inherent risks associated with percutaneous dilatational tracheostomy include loss of airway during endotracheal tube manipulation, inability to cannulate the trachea below the endotracheal tube, and difficulties related to neck anatomy. Percutaneous dilatational tracheostomy technique was modified to make the incision in the suprasternal area, and the use of air leak technique confirmed tracheal penetration below the endotracheal cuff. Bronchoscopy was not used. One hundred patients underwent percutaneous dilatational tracheostomy using the modification mentioned above. Although three patients had minor bleeding complications, there was no loss of airway; nor were there other complications. This technique provides improved safety from loss of airway and illuminates the need for concomitant bronchoscopy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.